Searching for a 45/5 capacitor, a 35/5 capacitor or a 70/7.5 dual run capacitor? The numbers printed on your old capacitor tell you exactly what to buy. This chart and checklist explain how to read them, which sizes are common in home AC units and heat pumps, and when a round capacitor can replace an oval one.
What the two numbers on a dual run capacitor mean
A dual run capacitor is two capacitors in one can. It runs both the compressor and the outdoor fan motor, which is why it has three terminals:
- HERM: the compressor (hermetic) side. This is the larger number, such as the 45 in 45/5.
- FAN: the condenser fan motor side. This is the smaller number, such as the 5 in 45/5.
- C: common. It is shared by both sides.
The rating is in microfarads (µF, also written MFD or uF). 45+5 µF, 45/5 MFD and 45-5 uF all describe the same capacitor.
Dual run capacitor size chart
The sizes below cover most residential split systems and heat pumps. Match both numbers on your old capacitor.
| Size (HERM + FAN) | Shape | Voltage | Typical use | CoralVolt part |
|---|---|---|---|---|
| 5 + 5 µF | Oval | 370/440V | Fan motor / small condenser | 5+5 µF oval |
| 7.5 + 5 µF | Oval | 370/440V | Fan motor / small condenser | 7.5+5 µF oval |
| 10 + 5 µF | Oval | 370/440V | Fan motor / small condenser | 10+5 µF oval |
| 35 + 5 µF | Round | 370/440V | Residential condenser | 35+5 µF round |
| 40 + 5 µF | Round | 370/440V | Residential condenser | 40+5 µF round |
| 45 + 5 µF | Round | 370/440V | Residential condenser (one of the most common sizes) | 45+5 µF round |
| 50 + 5 µF | Round | 370/440V | Residential condenser | 50+5 µF round |
| 55 + 5 µF | Round | 370/440V | Larger residential condenser | 55+5 µF round |
| 60 + 5 µF | Round | 370/440V | Larger residential condenser | 60+5 µF round |
| 70 + 7.5 µF | Round | 370/440V | Larger residential condenser | 70+7.5 µF round |
Capacitor size is set by the compressor and fan motor, not by tonnage alone. Always go by the label on the old capacitor or your unit's wiring diagram.
How to match a replacement capacitor in 4 checks
- Microfarads must match. Use the same HERM and FAN values. Do not swap a 45/5 for a 40/5 because it is in stock. A wrong value makes the compressor or fan run hot and shortens its life.
- Voltage can be the same or higher, never lower. A 440V capacitor can replace a 370V capacitor. A 370V capacitor must not replace a 440V one. CoralVolt dual run capacitors are rated 370/440V, so they cover both.
- Shape only has to fit. Round and oval capacitors with the same rating work the same way electrically. Choose the shape that fits your mounting bracket and the space in the panel.
- Terminals must line up. Make sure there are separate C, HERM and FAN terminals with enough tabs for the wires you are moving over.
Round vs oval: is a "60 oval dual run capacitor" different from a round one?
No. A 60/5 oval and a 60/5 round have the same rating. If the round version fits your bracket and you can route the wires, it is a direct replacement. Universal mounting straps hold most round sizes.
370V vs 440V capacitors
The voltage rating is the maximum the capacitor can safely handle, not the voltage it "needs". That is why a 440V capacitor is a safe upgrade for a 370V one. It is often the longer-lasting choice in hot climates.
Signs your capacitor is the problem
- The outdoor fan doesn't spin, or starts only when nudged with a stick (power off first).
- The compressor hums but doesn't start, or the breaker trips.
- The top of the capacitor is domed or bulging, or it is leaking oil.
- A meter reading is outside the tolerance printed on the label (usually ±5% or ±6%).
Not sure whether it's the capacitor or the contactor? Read AC contactor vs capacitor: which one failed. To test before you buy, see how to test an HVAC capacitor with a multimeter.
Safety first
Turn off power at the outdoor disconnect and the breaker. Capacitors can hold a dangerous charge even with the power off, so discharge the capacitor safely before touching the terminals. Take a photo of the wiring before you remove anything. If you're not comfortable working around high voltage, call a licensed HVAC technician.
FAQ
Can I use a 45/5 capacitor instead of a 40/5?
No. Match both values to the original. The tolerance is only a few percent, and 45 µF is about 12% higher than 40 µF.
What does MFD mean on a capacitor?
MFD is an older way of writing microfarad. It is the same as µF or uF.
Is a dual run capacitor the same as a start capacitor?
No. A run capacitor stays in the circuit the whole time the motor runs. A start capacitor (often part of a "hard start" kit) only helps the compressor get going.
Do I need the same brand?
No. The brand doesn't matter as long as the µF values, the voltage (same or higher) and the fit match. CoralVolt capacitors are CBB65 metallized-film capacitors listed as UL rated, and they replace common OEM parts used by Carrier, Trane, Goodman, Lennox, Rheem and others.
Find your size: browse all CoralVolt dual run capacitors. Technician multi-packs are available, and many sizes also come as singles.